GOST 22011-95

INTERSTATE STANDARD

PASSENGER ELEVATORS
AND CARGO

TECHNICAL CONDITIONS

INTERSTATE COUNCIL
ON
Minsk

Foreword

1 DEVELOPED TC 209 "Elevators and construction hoists"

INTRODUCED by the State Standard of Russia

2 ADOPTED by the Interstate Council for Standardization, Metrology and Certification (Protocol No. 8-95 of October 12, 1995)

State name

Name of the national standardization body

The Republic of Azerbaijan

Azgosstandart

Republic of Belarus

Belstandard

The Republic of Kazakhstan

Gosstandart of the Republic of Kazakhstan

Kyrgyz Republic

Kyrgyzstandart

The Republic of Moldova

Moldovastandart

Russian Federation

Gosstandart of Russia

The Republic of Tajikistan

Tajik State Center for Standardization, Metrology and Certification

Turkmenistan

Main State Inspectorate of Turkmenistan

The Republic of Uzbekistan

Uzgosstandart

State Standard of Ukraine

3 By the Resolution of the Committee of the Russian Federation for Standardization, Metrology and Certification No. 68 dated February 15, 1996, the interstate standard 22011-95 was put into effect directly as state standard Of the Russian Federation since January 1, 1997

4 REPLACE GOST 22011-90

5 REVISION

GOST 22011-95

INTERSTATE STANDARD

PASSENGER AND FREIGHT ELEVATORS

Technical conditions

Passenger and goods lifts. Specifications

Date of introduction 1997-01-01

1 AREA OF USE

This standard applies to electric passenger, hospital, freight and small freight elevators (hereinafter referred to as elevators).

The standard does not apply to elevators:

Passenger with a nominal speed (hereinafter referred to as speed) 2.0 m / s or more;

Freight sidewalk;

Ship;

Special purpose;

For work in buildings and premises classified into categories A and B * for explosion and fire hazard;

For work in rooms with corrosive vapors or gases;

For operation in conditions of condensation in a mine or machine room, frost or ice formation on equipment.

* Categories of buildings and premises for explosion and fire hazard are determined at the design stage of buildings and structures in accordance with the requirements of national standards in the field of fire hazard.

The requirements of this standard are mandatory.

Mandatory requirements for the quality of elevators, ensuring their safety for life, health and property of the population, environmental protection, are set out in the section.

2 REFERENCES

This standard uses references to the following standards and documents of state supervision:

The main parameters and dimensions of electric freight elevators are in accordance with GOST 8823.

The main parameters and dimensions of electric freight small elevators are in accordance with GOST 8824.

The designation of the elevators is given in the appendix.

4 TECHNICAL REQUIREMENTS

4.1 Features

4.1.2 The installation of elevators for work in buildings and premises classified by explosion and fire hazard category B should be carried out in accordance with the requirements of national building codes and regulations for lifts of this category.

4.1.3 Installation of elevators in buildings and structures located in areas with a seismic impact of 7-9 points is allowed if the requirements that take into account the operating conditions specified in the regulatory or design documentation are met.

4.1.4 The values ​​of the parameters of the lifts must correspond to those given in tables and.

4.1.5 Elevators must operate in the operating modes indicated in the table and maintain an operable state at an altitude of up to 2000 m above sea level.

When the elevator is operated at an altitude of 1000 to 2000 m, the number of starts per hour is reduced by 1% for every 100 m.

4.1.6 Elevators are made to operate from an alternating current with a frequency of 50 Hz and a voltage of 380 V.

Table 1

Passenger elevators

for residential buildings

for public buildings and industrial buildings

for industrial buildings

sick leave

Rated speed, m / s

Assigned service life, years

Accuracy of stopping the elevator car, mm, with a drive:

Adjustable

Unregulated

A, no more

Sound level in the cab when opening and closing doors, dB A, no more

Vibration speed of the cabin floor with steady motion, m / s, no more

Corrected winch sound power level, dB A, not less

Carrying capacity, kg

800; 1000; 1250; 1600

Note - At the end of the designated lifespan of the elevator, it is inspected in accordance with the procedure established by Gosgortekhnadzor.

Table 2

Freight elevators

Rated speed, m / s

Mean time between failures, h, not less

Assigned service life, years

Sound level in the cab with steady motion, dB A, no more

Vibration speed, m / s, no more

Corrected winch sound power level, dB A, no more

Carrying capacity, kg

2000 and more

* For elevators with a lifting capacity of 5000 kg.

** For lifts with a lifting capacity of 4000 and 6300 kg.

Note - At the end of the designated lifespan of the elevator, it is inspected in accordance with the procedure established by Gosgortekhnadzor.

Table 3

Rated speed, m / s

Working hours

Number of starts per hour, no more

Relative duration of PV activation,%, no more

Passenger

for residential buildings

for buildings of public and industrial enterprises

sick leave

for industrial buildings

Cargo

clutch release, with monorail

Cargo small

* For lifts with a lifting capacity of St. 630 kg

Table 4

Climatic version

Limiting operating temperatures, ° С

Upper value of relative air humidity

machine room

Passenger

for residential buildings, buildings of public and industrial enterprises, hospital

+40 to +1

80% at + 25 ° С

80% "+ 25 ° C

+55 to +1

98% at + 35 ° С

98% "+ 35 ° C

for industrial buildings

+40 to -40

98 % at + 25 ° С

80% "+ 25 ° C

Cargo

normal, clutch release, with monorail

+40 to -20

98% at + 25 ° С

98% "+ 25 ° C

+45 to -10

98% at + 35 ° С

98% "+ 35 ° C

Cargo small

+40 to +1

80% at + 25 ° С

* When recording the climatic performance of the elevator, the category of its placement is indicated by the category of the location of the machine room.

At the request of the customer, elevators can be manufactured for operation from the alternating current network:

Frequency 50 Hz with voltage 240 and 415 V;

Frequency 60 Hz "220; 230; 380; 400; 415 and 440 V.

Elevators must be operational when connected to an alternating current network with deviations from their rated values ​​of current frequency of no more than 1% and voltage of no more than 10%.

4.1.7 Radio interference arising from the operation of the elevator should not exceed the values ​​established by GOST 23511 and national standards for permissible industrial radio interference. The field strength of the radio interference generated by the elevator is not standardized.

4.1.8 Elevators, depending on the operating conditions, should be made of climatic versions and placement categories (according to GOST 15150), given in the table.

4.1.9 Cabins of freight elevators with solid doors, except for externally controlled elevators, as well as passenger elevators for residential and public buildings and industrial buildings must have natural ventilation.

The cabins of passenger, hospital and freight elevators (with a conductor) with solid doors in tropical design must have natural and forced ventilation.

4.1.9.1 Passenger elevators with automatic doors at a speed of 1.0 m / s and more must have a "fire hazard" operating mode, which is activated by a signal from the building's automatic fire alarm systems and provides, regardless of the load and the direction of movement of the car, the return it to the main landing site, opening and holding open the doors of the cabin and the shaft.

4.1.9.2 Passenger elevators intended for the transportation of fire brigades must have a mode of operation "transportation of fire brigades". The transfer of the elevator control to this mode should be carried out from the cabin, while the control system should ensure the operation of the elevator only by orders from the cabin.

4.1.10 The cladding of the compartment compartment, shades, flooring, as well as buttons for orders and call stations should be made of non-combustible or hardly combustible materials.

4.1.11 In the roof of the elevator car used for the transportation of fire departments, a hatch with a size of at least 700x500 mm must be provided. The hatch must be equipped with a switch that controls its locking.

4.1.12 Doors of the elevator shaft must be fireproof of the second type and comply with the requirements of SNiP 21-01 (sections 3 and 4).

Fire resistance limit of mine doors passenger elevator for residential buildings with speeds up to 1.0 m / s incl. not installed.

The doors of the cargo elevator shaft may not be equipped with a self-closing device.

Small freight elevators with two stops are allowed to be performed in a metal-frame shaft with a fence made of metal sheets. At the same time, fire safety requirements are not imposed on shaft doors.

4.1.13. The system of electric drive and automation of elevators should provide the ability to connect external systems for monitoring the operation of the elevator and identifying its faults.

Requirements for elevator control and signaling devices are in accordance with GOST 28911. When installing a group of two or more passenger elevators with the same rated speed and, as a rule, the number of stops, a group control system with a common control ringing device should be used at each landing site.

4.1.14 Signal colors and safety signs - in accordance with GOST 12.4.026 and GOST 28911, respectively.

Wherein:

The surfaces of grease fittings, caps, drain plugs, oil indicators must have a red coating;

The surfaces of the rotating parts, not covered by the casing, except for the surfaces of the rotating parts on the rope tensioner of the speed limiter and the counterweight, must have a yellow coating.

It is allowed to paint the end surfaces of parts of rotation in the form of an annular strip with a width of at least 20 mm in accordance with the indication of the place of painting on the drawings.

Passenger elevators with a mode of operation "transportation of fire brigades" must have distinctive symbols located on the main landing site, in accordance with the instructions of the design documentation.

4.1.15 Technical documentation for the elevator must comply with the requirements of the elevator design project, approved in the prescribed manner.

4.1.16 The paint and varnish coatings of the surfaces of the lift equipment must correspond to the coating classes indicated in the table.

Table 5

Surfaces component parts elevators located in the shaft, machine room and block room, including:

Outer surfaces of cab fencing (shields);

Non-front surfaces of the doors of the cab and shaft doors;

Guides for the cab and counterweight, except for the working surface of the head of the T-profile guides;

Details (except for fasteners) and assembly units for fastening car rails and counterweight;

Surfaces of the cabin frame and counterweight, brackets for fastening shunts and sensors in the mine and on the cabin, metal structures for installing blocks, buffers, tensioning devices, transformers and other electrical equipment, frame and subframes of the winch;

Untreated surfaces of blocks and pulleys, grounding bars;

Cast iron counterweight and rope tensioner weights, speed limiter

The inner surfaces of the passenger elevator car, not visible from the inside. The inner surfaces of the freight elevator car, visible from the inside.

Untreated surfaces of gearbox, handwheel, winch brake, speed limiter, hydraulic buffer

The inner surfaces of the passenger elevator car, visible from the inside.

The front surfaces of the doors of the cab and shaft doors, if they do not have another decorative finish

IV, III (at the request of the customer)

Metal coatings must comply with GOST 9.301. Equipment for tropical climatic elevators is painted in accordance with GOST 9.401.

4.1.17 The equipment of the freight elevator, as agreed with the customer, is allowed to be coated with a primer followed by painting after installation.

Lack of coloring in hard-to-reach places is allowed.

Hard-to-reach places should be indicated in the design documentation.

It is allowed not to cover the cast iron weights of the counterweight and the tensioner of the elevator speed limiter.

4.1.18 The front side of the shaft door leaves of one or more elevators must have a coating of one color and one shade at each stopping site, unless otherwise requested by the customer.

4.1.19 The places of welding (welded seams and heat-affected surfaces) made during the installation of the elevator must be protected by the coating provided for them in technical documentation to the elevator.

4.1.20 Ropes should be of measured length from one coil and with a cleaned surface. Dirt and other inclusions on the surface of the ropes are not allowed.

The ends of the ropes must be protected from unwinding, and at the cut-off point they must be made in accordance with 2.1.9 GOST 3241.

4.1.21 The overhead electric cable of the elevator must be cut, with terminated and marked wires.

Wiring harnesses throughout the mine and machine room must be labeled. By agreement with the customer, delivery of measured length wires is allowed.

4.2 Completeness

4.2.1 The lift kit should include:

Elevator equipment in accordance with the elevator specification, incl. spare parts and materials designed for the warranty period of the elevator operation, tools and accessories (spare parts) required for Maintenance and repair of the elevator; spare parts for commissioning during installation (ZIM) in accordance with their lists;

The technical documentation sent with the lift and the Replacement Parts List according to the applications and accordingly.

In the case of sending several elevators of the same type, type, carrying capacity, speed and performance ( different location counterweight, walk-through or non-walkable car, etc.) for installation at one facility or building, technical documentation is sent in one copy for 5 elevators. Passport, principled electrical circuit, wiring diagram, assembly (installation) drawing should be sent with each lift.

4.2.2 The components of the elevator: winch, cabin, shaft doors, hydraulic buffer, speed limiter, tensioner should be sent assembled and adjusted, unless otherwise requested by the customer.

Mounting brackets for floor switches, shunts, selection sensors, floor terminal boxes should be shipped with clamps attached. Rail fastening parts should be sent assembled with clamps attached.

4.2.3 Disassembled, it is allowed to send:

Counterweight;

Freight elevator cabin with dimensions in terms of 1500x2000 mm and more;

Hospital elevator cabin for buildings of medical and preventive institutions;

Freight lift shaft doors with an opening width of more than 2000 mm or a height of more than 2600 mm;

Framing (if any) of the openings of the mine doors of passenger elevators.

4.3 Marking

4.3.1 Each lift must be provided with a plate made in accordance with GOST 12969, GOST 12970 and GOST 12971.

The elevator plate must indicate:

The name or trademark of the lift manufacturer;

Marking of lift equipment packages for the Far North of the Russian Federation and hard-to-reach areas (for example, mountainous, etc.) - in accordance with GOST 15846.

4.4 Packaging

4.4.1 The components of the elevator equipment must be preserved before packing.

Temporary anti-corrosion protection - in accordance with GOST 9.014.

The use of conservation oils for the preservation of ropes is not allowed. They can be used to cover the surface of the T-profile guides.

Preservation of the components of the elevator equipment should ensure their protection until the first re-preservation: the components of the elevator - up to one year, spare parts - up to 2.5 years. Re-preservation must be carried out by the owner of the lift.

The packing lists must indicate: the date and period of re-preservation, as well as the means of temporary corrosion protection.

4.4.2 Preservation and packing of wires and cables should be carried out taking into account the requirements of GOST 18690, electrical equipment (including harnesses) - in accordance with GOST 23216.

4.4.3 Packing of equipment and technical documentation of the elevator - in accordance with GOST 23170.

Ropes are packed in a polymer film in accordance with GOST 10354 or other NTD agreed with Gosgortekhnadzor, or in waterproof paper in accordance with GOST 8828 and GOST 515.

A rope wound into a coil must be tightly tied with soft wire (in accordance with GOST 3282 or other NTD) or a strand of the same rope, or with a tape in accordance with GOST 3560 (or other NTD) in at least four places evenly spaced around the circumference.

4.4.4 Packaging of lift equipment in a tropical climatic version must comply with the requirements of GOST 24634, while the timber for packaging must be impregnated with an antiseptic. Instead of antiseptic treatment, it is allowed to paint boxes in two layers with PF-115 gray paint in accordance with GOST 6465 or other similar paints.

4.4.5 Packing of elevator equipment sent to the Far North of the Russian Federation and hard-to-reach areas - in accordance with GOST 15846.

5 SAFETY REQUIREMENTS

The safety of elevators is ensured by fulfilling a set of requirements - (except, -,), sections, -, this standard and PUBEL Gosgortechnadzor.

6 RULES OF ACCEPTANCE

6.1 Component parts (equipment) of the elevator (including spare parts and accessories) should be subjected to acceptance control by the manufacturer's technical control service in order to determine their suitability for shipment to the consumer.

6.2 Acceptance control of the components of the elevator must be statistical on an alternative basis in accordance with GOST 18242.

Parameters, dimensions, requirements to be controlled, sample size and types of defects must be indicated in the technical documentation for the elevator.

a) control plan:

Control level - II,

Control plan type - one-stage,

b) the acceptance level of defectiveness of the winch, gearbox (if it is produced as replacement part), elevator door drive, speed limiter, safety devices, hydraulic buffer, cabin loading control device, shaft doors, cabin doors, critical springs (buffer springs, brakes, safety gears, cabin suspensions and counterweight, etc.), spare parts and accessories :

2.5% for significant defects;

6.5% for minor defects.

Acceptance level of defectiveness of the rest assembly units and equipment parts:

0% - for critical defects;

6.5% for significant defects.

The production cycle under continuous statistical control is one year.

6.4 Purchased products, materials and raw materials should be subject to incoming inspection in accordance with GOST 24297.

During the incoming inspection, the low-voltage complete device (ASSEMBLY) must be checked for functioning.

When the customer or the consumer of the elevators receives complaints or claims to the quality of the purchased product, the manufacturer of the elevator during the incoming inspection must use another more stringent type of control in accordance with GOST 18242.

6.5 Elevator components, parts and castings produced by other manufacturers Shall be visually inspected by the elevator manufacturer to detect possible damage to this equipment during transportation.

The manufacturer of equipment, parts and castings, upon receipt of claims from the manufacturer of the elevator, must inform him within 3 days of the decision taken to eliminate the defect.

6.6 Acceptance tests of the components (equipment) of the elevator

The components of the elevator mentioned in must be subjected to acceptance tests by its manufacturer according to programs and procedures approved in the prescribed manner.

The sampling volume of samples of the elevator components is set by the elevator manufacturer and is indicated in the technical documentation.

After making a prototype:

Preliminary;

Acceptance;

When mastering production - qualification;

For serial production:

Acceptance tests of the elevator components;

Periodic;

Typical.

6.8 The frequency of the elevator tests specified in, the number of elevators that should be subjected to these tests, and the number of elevators in the batch from which the elevator is selected for testing shall correspond to the table.

6.9 Periodic testing

6.9.1 Periodic tests of the elevator are carried out in order to check the stability of the workmanship and the possibility of continuing its release.

Periodic tests should include verification of all mandatory requirements established by this standard and PUBEL Gosgortekhnadzor.

6.9.2 In case of unsatisfactory results of periodic tests at least one of the points of the program, repeated tests should be carried out on these points on a double number of the corresponding components of the lift, taken from the same batch. Retest results are final.

Table 6

Frequency of tests

Number of lifts

The number of lifts in the batch from which the lifts are selected for testing

Preliminary

One-time - after making prototypes

All prototypes of the elevator, the number of which is determined terms of reference to develop

Receiving

All pre-tested prototypes

Qualifying

When putting into production an elevator of this model

Not less than 3

Periodic

At least once every three years

Not less than 7 *

With every design change

Not less than 3

* When carrying out tests at the manufacturer, the elevators are selected from among those that have passed the acceptance control and are ready for shipment to the consumer. When carrying out tests at the operating facility, they are selected from the number of manufactured ones no more than 18 months before the start of the tests.

7 CONTROL METHODS

7.1 Requirements for measuring instruments

7.1.1 Measuring instruments shall be verified in accordance with the requirements of GOST 8.002 and GOST 8.513.

Test equipment must be certified in accordance with GOST 24555, non-standardized measuring instruments must pass metrological certification in accordance with GOST 8.326.

7.2 Test preparation

7.2.1 Prior to the acceptance and qualification tests of the elevator, tests for the reliability of the winch, drive of doors, car doors, shaft doors, speed limiters, safety devices, hydraulic buffers, and car loading control devices must be performed.

It is allowed not to carry out tests for the reliability of equipment borrowed from other elevators, provided that it has been tested earlier and the manufacturer has a justification for maintaining the reliability indicators under operating conditions.

A low-voltage complete device must have a document confirming its reliability.

7.2.2 Before carrying out periodic tests, the manufacturer must provide materials confirming the reliability indicators of the elevators.

Confirmation of reliability indicators is carried out on the basis of a test for the reliability of an elevator or its components (equipment) in the period between periodic tests or on the basis of the results of operational observations of the operation of similar elevators.

Methods and plans of tests for reliability and observations during operation - in accordance with GOST 27.410.

7.2.3 To type test an elevator that uses equipment with modifications that could affect technical characteristics the elevator and / or its operation, tests should be carried out for each modified equipment.

If the test results of the modified equipment are positive, it is allowed to carry out type tests of the elevator.

7.3 Carrying out elevator tests

7.3.1 Tests of elevators should be carried out in accordance with agreed in the prescribed manner.

7.3.1.1 Before the start of the lift tests, the manufacturer must have a "Certificate of technical readiness of the lift".

The tests must be carried out on the premises of the lift manufacturer. Carrying out tests of the elevator at the operation site must be agreed with the Gosgortekhnadzor.

It is not allowed to replace the tests of the elevator by testing its layout.

When testing group control of elevators with three or more elevators in a group, it is allowed to simulate this system.

When testing several elevators of the same type and type, it is allowed to determine quantitative and quality characteristics one elevator - a typical representative of the group (determined by the elevator developer). For the rest of the elevators in the group, characteristics that differ from the characteristics of the typical representative must be checked.

In case of unsatisfactory test results for one or several indicators, the resumption of repeated tests is allowed only after the causes of the deficiencies are established and their elimination.

8 TRANSPORTATION AND STORAGE

8.1 Transportation of elevator equipment is allowed to be carried out by any type of transport in accordance with the transportation rules applicable to them.

When transporting elevator equipment on ship decks, the elevator manufacturer must take into account the effect of a type III atmosphere in accordance with GOST 15150.

8.2 Conditions and terms of storage and transportation of elevator equipment, spare parts and accessories in the packaging and (or) preservation of the manufacturer must correspond to those indicated in the table.

Table 7

It is allowed to store elevator equipment under storage conditions 8 in accordance with GOST 15150 both at the manufacturer and at the customer for 3 months, with a total shelf life of no more than 6 months.

9 INSTALLATION AND OPERATING INSTRUCTIONS

9.1 Installation of elevators should be carried out in accordance with the requirements of GOST 22845, PUBEL Gosgortekhnadzor and technical documentation for the installation of the elevator.

9.2 The operation of the elevators must be carried out in accordance with the requirements of PUBEL Gosgortekhnadzor and the operating instructions.

10 MANUFACTURER'S WARRANTY

The manufacturer guarantees the compliance of the elevator (as a whole, including components and components) with the requirements of this standard, provided that the requirements for operation, storage, transportation and installation are met.

The warranty period is 18 months from the date of signing the "Certificate of acceptance of the elevator".

APPENDIX A

1 Scheme of the symbol of passenger elevators

1 - type of elevator; LP - passenger elevator with basic parameters and design in accordance with GOST 5746;

2 - group of conventional designation of the main parameters of the elevator (carrying capacity and rated speed), set in accordance with the methodology in force in the elevator industry of the CIS countries;

3 - an indication of the installation of an elevator - single (they do not indicate in the symbol), group (G) from group 2 - 4, 6 elevators (G2 - G4, G6);

4 - the number of elevator stops;

5 -

6 -

7 - indication of the presence of the elevator operating mode "transportation of fire departments" (P);

8 -

Example of a symbolpassenger elevator for residential buildings with the main dimensions and design in accordance with GOST 5746, with a carrying capacity of 400 kg, with a nominal speed of 0.71 m / s, single installation, with 10 stops, designed for operation in a moderately cold climate zone, placement categories 4 and in an area with an intensity of seismic impact of 8 points, which does not have a mode of operation "transportation of fire brigades":

2 Scheme of the symbol of freight elevators

1 - type and type of elevator with parameters, basic dimensions and design in accordance with GOST 8823:

Regular freight elevator (LGO);

Freight release lift (LGV);

Freight elevator with monorail (LGOM);

2 - serial registration number of the elevator model;

3 - carrying capacity, kg;

4 - rated speed, m / s;

5 - lifting height, m;

6 - number of stops;

7 - an indication of the size of the cabin in terms of an elevator of a given carrying capacity - the first (the smaller one is not indicated in the symbol) or the second (larger) (B);

8 - cab type - checkpoint (Ex.), non-passable (Continuous);

9 - climatic version and category of elevator placement;

10 - an indication of the execution of the elevator (execution without taking into account the seismic effect in the symbol is not indicated), taking into account the seismic effect (C) with an intensity of 7 - 9 points (C7 - C9);

11 - designation of this standard.

Example of a symbolfreight elevator with basic dimensions and design in accordance with GOST 8823, with ordinal registration number 922, with a lifting capacity of 1000 kg, with a nominal speed of 0.4 m / s, a lift height of 60 m, with 16 stops, with a walk-through cab of the second dimension, for operation in a moderately cold climate zone and placement category 4:

LGO 922 1000 x 0.4 60 16 B Pr UHL4 GOST 22011-95

3 Scheme of symbolic designation of cargo small elevators

1 - type of elevator; LGM - small freight elevator with parameters, basic dimensions and design in accordance with GOST 8824;

2 - serial registration number of the elevator model;

3 - carrying capacity, kg;

4 - rated speed, m / s;

5 - lifting height, m;

6 - number of stops;

7 - view of the cabin - through (Well), blind (Nesqu.);

8 - climatic version and category of elevator placement;

9 - designation of this standard.

Example of a symbolsmall freight elevator with parameters, basic dimensions and design in accordance with GOST 8824, with registration number of model 958, carrying capacity 100 kg, with a nominal speed of 0.4 m / s, lifting height 45 m, with the number of stops 14, with a blind cabin, in version for operation in a moderately cold climate zone and with placement category 4:

LGM 958 100 x 0.4 45 Nesqu. UHL4 GOST 22011-95

APPENDIX B

(required)

* Depending on the type and type of a particular elevator, the list of documents for its equipment is specified by the developer.

The set of technical documentation for the elevator includes the following documents:

Elevator passport according to PUBEL Gosgortekhnadzor with documents certifying the quality: winches, speed limiter, door drive, hydraulic buffer, cabin buffer springs and counterweight, brake springs, safety springs. NKU passport (stored together with the elevator passport);

Installation drawing (installation drawing, a sample of which has been approved by Gosgortekhnadzor) (2 copies);

Instructions for installation, start-up, regulation and running-in;

Technical description and operating instructions;

Basic electrical diagram with a list of elements (3 copies);

Description of the electric drive and automation (it is allowed to supply as part of technical description and operating instructions);

Electrical wiring diagram of the LVL for elevator control (supplied with the LVCD);

Elevator wiring diagram;

Vedomosti SPTA and ZIM;

Replacement parts drawings (see appendix);

Assembly drawings (and specifications for them) of elevator equipment for: speed limiter, hydraulic buffer, winch, reducer, brake, clutch, branch block, cabin, safety devices, automatic door drive, shaft door, automatic and manual shaft door locks, wiring for machine room, mine and cabin, counterweight.

APPENDIX B

* The parts indicated in the list are intended to replace those that have failed (wear, breakdown) during the operation of the elevator after the expiration of its warranty period

Traction pulley.

Brake shoe assembly.

Brake spring.

Cab slip shoe liner.

Cab shoe roller (s).

Sliding door insert for freight elevators.

Shoe for doors of passenger elevators.

Roller for the doors of freight elevators.

Roller for carriages of passenger elevator cabin doors.

Roller drove drive doors of passenger elevators.

Rubber stop for the drive of the cab doors.

Counterweight sliding shoe bushing.

Roller carriages of automatic sliding doors of the mine.

Roller rubberized for the lock of the doors of the mine.

Speed ​​limiter pulley.

Elevator traction rope outlet block.

V-belt drive pulleys of the cab door drive.

Rubber ring of the device for controlling the loading of the moving field of the cab.

Cab door drive belt.

Note - The list of details is specified for a specific elevator by its developer.

Key words: passenger elevators, freight and freight small elevators, technical requirements, safety requirements, acceptance rules, transportation and storage

    Appendix A (recommended). Schemes for constructing a symbol for electric passenger, freight and small freight elevators Appendix B (mandatory). List of technical documentation set Appendix B (recommended). Replacement Parts List

Interstate standard GOST 22011-95
"Passenger and freight elevators. Technical conditions"
(put into effect by the decree of the State Standard of the Russian Federation of February 15, 1996 N 68)

With changes and additions from:

Passenger and goods lifts. Specifications

6.9. Periodic tests

6.9.1. Periodic tests of the elevator are carried out in order to check the stability of the quality of manufacture and the possibility of continuing its release.

Periodic tests should include verification of all mandatory requirements established by this standard and PUBEL Gosgortekhnadzor.

6.9.2. If the results of periodic tests are unsatisfactory for at least one of the points of the program, repeated tests for these points should be carried out on a double number of the corresponding components of the elevator taken from the same batch. Retest results are final.

Table 6

Test type Periodicity
trials
Quantity
elevators
Number of lifts
in the party, from
which is selected
elevators for
trials
Preliminary One-time - after
making
prototypes
All elevator prototypes,
the number of which is determined
terms of reference for
elaboration
Receiving Also 1 All experienced
samples passed
preliminary
trials
Qualifying When setting on
elevator manufacturing
this model
1 Not less than 3
Periodic At least once
at 3 years old
1 Not less than 7
Typical At every
change
constructions
1 Not less than 3
* When tested by the manufacturer, the elevators are selected from
passed the acceptance control and ready for shipment to the consumer. At
testing at the facility is selected from among
manufactured no more than 18 months before the start of tests

7. Methods of control

7.1. Requirements for measuring instruments

7.1.1. Measuring instruments must be verified in accordance with the requirements of GOST 8.002 and GOST 8.513.

Test equipment must be certified in accordance with GOST 24555, non-standardized measuring instruments must pass metrological certification in accordance with GOST 8.326.

7.2. Test preparation

7.2.1. Prior to the acceptance and qualification tests of the elevator, tests for the reliability of the winch, drive of doors, car doors, shaft doors, speed limiters, safety devices, hydraulic buffers, and car loading control devices must be performed.

It is allowed not to carry out tests for the reliability of equipment borrowed from other elevators, provided that it has been tested earlier and the manufacturer has a justification for maintaining the reliability indicators under operating conditions.

A low-voltage complete device must have a document confirming its reliability.

7.2.2. Before carrying out periodic tests, the manufacturer must provide materials confirming the reliability indicators of the elevators.

Confirmation of reliability indicators is carried out on the basis of a test for the reliability of an elevator or its components (equipment) in the period between periodic tests or on the basis of the results of operational observations of the operation of similar elevators.

Methods and plans of tests for reliability and observations during operation - in accordance with GOST 27.410.

7.2.3. For type testing of an elevator that uses equipment with modifications that could affect the technical characteristics of the elevator and / or its operation, each modified equipment must be tested.

If the test results of the modified equipment are positive, it is allowed to carry out type tests of the elevator.

7.3. Elevator Testing

7.3.1. Tests of elevators should be carried out in accordance with the Programs and test methods agreed in the prescribed manner.

7.3.1.1. Before testing the elevator, the manufacturer must have a "Certificate of technical readiness for the elevator".

The tests must be carried out on the premises of the lift manufacturer. Carrying out tests of the elevator at the operation site must be agreed with the Gosgortekhnadzor.

It is not allowed to replace the tests of the elevator by testing its layout.

When testing group control of elevators with three or more elevators in a group, it is allowed to simulate this system.

When testing several elevators of the same type and type, it is allowed to determine the quantitative and qualitative characteristics of one elevator - a typical representative of the group (determined by the elevator developer). For the rest of the elevators in the group, characteristics that differ from the characteristics of the typical representative must be checked.

In case of unsatisfactory test results for one or several indicators, the resumption of repeated tests is allowed only after the causes of the deficiencies are established and their elimination.

8. Transportation and storage

8.1. Transportation of elevator equipment is allowed to be carried out by any type of transport in accordance with the rules of transportation applicable to them.

GOST 15150 right now or request by Hotline in system.

Active Edition from 12.10.1995

"PASSENGER AND FREIGHT ELEVATORS. TECHNICAL CONDITIONS. GOST 22011-95" (approved by the State Standard of the Russian Federation)

INTERSTATE STANDARD Foreword

1 DEVELOPED TC 209 "Elevators and construction hoists"

INTRODUCED by the State Standard of Russia

2 ADOPTED by the Interstate Council for Standardization, Metrology and Certification (protocol N 8-95 dated October 12, 1995),

State nameName of the national standardization body
The Republic of AzerbaijanAzgosstandart
Republic of BelarusBelstandard
The Republic of KazakhstanGosstandart of the Republic of Kazakhstan
Republic of KyrgyzstanKyrgyzstandard
The Republic of MoldovaMoldovastandart
Russian FederationGosstandart of Russia
The Republic of TajikistanTajik State Center for Standardization, Metrology and Certification
TurkmenistanMain State Inspectorate of Turkmenistan
The Republic of UzbekistanUzgosstandart
UkraineState Standard of Ukraine

3 By the Resolution of the Committee of the Russian Federation for Standardization, Metrology and Certification No. 68 dated February 15, 1996, the interstate standard 22011-95 was put into effect directly as a state standard of the Russian Federation from January 1, 1997.

4 REPLACE GOST 22011-90

This standard cannot be fully or partially reproduced, replicated and distributed as an official publication on the territory of the Russian Federation without the permission of Gosstandart of Russia.

1 AREA OF USE

This standard applies to electric passenger, hospital, freight and small freight elevators (hereinafter referred to as elevators).

The standard does not apply to elevators:

Freight sidewalk;

Ship;

Special purpose;

For work in buildings and premises classified in categories A and B<*>on explosion and fire hazard;

<*>Categories of buildings and premises in terms of explosion and fire hazard are determined at the design stage of buildings and structures in accordance with the requirements of national standards in the field of fire hazard.

For work in rooms with corrosive vapors or gases;

For operation in conditions of condensation in a mine or machine room, frost or ice formation on equipment.

The requirements of this standard are mandatory.

Mandatory requirements for the quality of elevators, ensuring their safety for life, health and property of the population, environmental protection, are set out in section 5.

2. REGULATORY REFERENCES

GOST 8.002-86 GSI. State supervision and departmental control over measuring instruments. Basic Provisions

GOST 8.326-89 GSI. Metrological certification of measuring instruments

GOST 8.513-84 GSI. Verification of measuring instruments. Organization and procedure

GOST 9.014-78 ESZKS. Temporary anti-corrosion protection of products. General requirements

GOST 9.032-74 ESZKS. Paint and varnish coatings. Groups, technical requirements and designations

GOST 9.301-86 ESZKS. Metallic and non-metallic inorganic coatings. General requirements

GOST 9.401-91 ESZKS. Paint and varnish coatings. General requirements and methods of accelerated tests for resistance to climatic factors

GOST 12.4.026-76 SSBT. Signal colors and safety signs

GOST 27.410-87 Reliability in technology. Reliability Methods and Reliability Proof Test Plans

GOST 515-77 Bituminous and tar packing paper. Technical conditions

GOST 3241-91 Steel ropes. Technical conditions

GOST 3282-74 Low-carbon steel wire general purpose... Technical conditions

GOST 3560-73 Steel packing tape. Technical conditions

GOST 5746-83 Electric passenger lifts. Basic parameters and dimensions

GOST 6465-76 Enamels PF-115, Specifications

GOST 8823-85 Electric freight elevators. Basic parameters and dimensions

GOST 8824-84 Small electric freight elevators. Basic parameters and dimensions

GOST 8828-89 Base paper and two-layer waterproof packaging paper. Technical conditions

GOST 10354-82 Polyethylene film. Technical conditions

GOST 12969-67 Plates for machines and devices. Technical requirements

GOST 12970-67 Round plates for machines and devices. Dimensions (edit)

GOST 12971-67 Rectangular plates for machines and devices. Dimensions (edit)

GOST 14192-77 Marking of goods

GOST 15150-69 Machines, devices and others technical products... Versions for different climatic regions. Categories, operating conditions, storage and transportation in terms of the impact of climatic environmental factors

GOST 15846-79 Products sent to the Far North and hard-to-reach areas. Packaging, labeling, transportation and storage

GOST 18242-72 Statistical acceptance control on an alternative basis. Control plans

GOST 18690-82 Cables, wires, cords and cable accessories. Marking, packaging, transportation and storage

GOST 22845-85 Electric passenger and cargo lifts. Rules for the organization, production and acceptance of installation work

GOST 23170-78 Packaging for mechanical engineering products. General requirements

GOST 23216-78 Electrical products. General requirements for storage, transportation, temporary corrosion protection and packaging

GOST 23511-79 Industrial radio interference from electrical devices used in residential buildings or connected to their electrical networks. Norms and methods of measurements

GOST 24297-87 Incoming control of products. Basic Provisions

GOST 24555-81 SGIP, Procedure for the certification of test equipment. Basic Provisions

GOST 24634-81 Wooden boxes for products supplied for export. General specifications

GOST 28911-91 Elevators and small freight elevators. Control devices, alarms and additional devices

"Rules for the construction and safe operation of elevators" of the national technical supervision bodies for safe operation elevators

SNiP 2.01.02.85 Construction norms and rules. Fire protection standards

3. BASIC PARAMETERS AND DIMENSIONS

The main parameters and dimensions of electric passenger and hospital elevators are in accordance with GOST 5746.

The main parameters and dimensions of electric freight elevators are in accordance with GOST 8823.

The main parameters and dimensions of electric freight small elevators are in accordance with GOST 8824.

The designation of the elevators is given in Appendix A.

4. TECHNICAL REQUIREMENTS

4.1 Features

4.1.1 Elevators must meet or exceed the requirements of this standard, the "Rules for the Construction and Safe Operation of Elevators" of the national technical supervision bodies for the safe operation of elevators (hereinafter - PUBEL Gosgortechnadzor) and the "Rules for Electrical Installation" of the Ministry of Fuel and Energy.

4.1.2 The installation of elevators for work in buildings and premises classified by explosion and fire hazard category B should be carried out in accordance with the requirements of national building codes and regulations for lifts of this category.

4.1.3 Installation of elevators in buildings and structures located in areas with a seismic impact of 7-9 points is allowed if the requirements that take into account the operating conditions specified in the regulatory or design documentation are met.

4.1.4 The values ​​of the parameters of the lifts must correspond to those given in Tables 1 and 2.

4.1.5 Lifts must operate in the operating modes specified in Table 3, and maintain a working condition at an altitude of up to 2000 m above sea level.

When the elevator is operated at an altitude of 1000 to 2000 m, the number of starts per hour is reduced by 1% for every 100 m.

4.1.6 Elevators are made to operate from an alternating current with a frequency of 50 Hz and a voltage of 380 V.

Table 1

Indicator namePassenger elevators
for residential buildings
for industrial buildingssick leave
Rated speed, m / s
0,71 1,0 1,4 1,6 1,0 1,6 0,71 0,5 1,0 1,6
440 400 170 180 380
Assigned service life, no25
Accuracy of stopping the elevator car, mm, with a drive:
- adjustable± 10
- unregulated± 35
Sound level in the cab: with steady motion, dB A, no more55 70 55
Sound level in the cab: when opening and closing doors, dB A, no more60 - 60
Vibration speed of the cabin floor with steady motion, m / s, no more0.06 10 (-2)

End of table 1

Indicator namePassenger elevators
for residential buildingsfor public buildings and industrial buildings
for industrial buildingssick leave
Rated speed, m / s
0,71 1.0 1,4 1,6 1,0 1,6 0,71 0,5 1,0 1,6
Carrying capacity, kg320;
400
73 79 78 73 - 78 75 -
500 - 73 79 78 73 - 78 - 75 - -
630 - 73 -
800;
1000;
1250;
1600
- 78 -

table 2

Indicator nameFreight elevators
normalsmall
Rated speed, m / s
0,25 <*> 0,25 <**> 1.0 0,4,
0,5 0,4 0,5
Mean time between failures, h, not less300 350 350 300
Assigned service life, years25
Sound level in the cabin with steady motion, dB A, no more70 60 60 -
Vibration speed, m / s, no more0.32 10 (-2)0.16 10 (-2)0.16 10 (-2)-
Corrected winch sound power level, dB A, no moreCarrying capacity, kg100 - - - -
500 79 - - -
630 - 78 78 -
1000 79 78 78 -
1600 - - - -
2000 and more79

<*>For elevators with a lifting capacity of 5000 kg,

<**>For lifts with a lifting capacity of 4000 and 6300 kg.

Note - At the end of the designated lifespan of the elevator, its inspection is carried out in accordance with the procedure established by Gosgortekhnadzor.

Table 3

ElevatorRated speed, m / sWorking hours
Type ofViewNumber of starts per hour, no moreRelative duration of PV activation,%, no more
Passengerfor residential buildings0,4-0,71 120 60
1,0 - 1,6 150- 50
180 <*> 40
for buildings of public and industrial enterprises1,0; 1,6 180; 200 <*> 40
sick leave0,5 60 25
1,0 150 50
180 <*> 40
1,6 180; 200 <*>
for industrial buildings0,4-0,71 100 60
Cargonormal0,25 45 40
0,4; 0,5 60 25
1,0 120 60
clutch release, with monorail0,4; 0,5 60 25
Cargo small- 0,4; 0,5 75 40

<*>For elevators with a lifting capacity of St. 630 kg.

Table 4

ElevatorClimatic versionAccommodation category<*> Limiting operating temperatures, ° СUpper value of relative air humidity
Type ofViewminemachine room
Passengerfor residential buildings, for buildings of public and foam enterprises, hospitalUHL4 4 +40 to +180% at + 25 ° С
-"- +40 -"- +5 80% - "- + 25 ° С
O4 4 +55 to +198% at + 35 ° С
-"- +55 -"- +5 98% - "- + 35 ° С
for industrial buildingsUHL3 4 +40 to -4098% at + 25 ° С
-"- +40 -"- +5 80% - "- + 25 ° С
Cargonormal, clutch release, with monorailUHL3 4 +40 to -2098% at + 25 ° С
-"- +40 -"- +5 98% - "- + 25 ° С
THEN3 4 +45 to -1098% at + 35 ° С
-"- +45 -"- +5 98% - "- + 35 ° С
Cargo small- UHL4 4 +40 to +180% at + 25 ° C
-"- +40 -"- +5 80% - "- + 25 ° С

<*>When recording the climatic performance of the elevator, the category of its placement is indicated by the category of the location of the machine room.

At the request of the customer, elevators can be manufactured for operation from the alternating current network:

Frequency 50 Hz with voltage 240 and 415 V;

Frequency 60 Hz with voltage 220; 230; 380; 400; 415 and 440 V. Elevators must be operational when connected to

AC networks with deviations from their rated values ​​of current frequency not more than 1% and voltage not more than 10%.

4.1.7 Radio interference arising from the operation of the elevator should not exceed the values ​​established by GOST 23511 and national standards for permissible industrial radio interference. The field strength of the radio interference generated by the elevator is not standardized.

4.1.8 Elevators, depending on the operating conditions, should be manufactured in climatic versions and placement categories (according to GOST 15150), given in Table 4.

4.1.9 Cabins of freight elevators with solid doors, except for externally controlled elevators, as well as passenger elevators for residential and public buildings and industrial buildings must have natural ventilation.

The cabins of passenger, hospital and freight elevators (with a conductor) with solid doors in tropical design must have natural and forced ventilation.

4.1.9.1 Passenger elevators with automatic doors at a speed of 1.0 m / s and more must have a "fire hazard" operating mode, which is activated by a signal from the building's automatic fire alarm systems and provides, regardless of the load and the direction of movement of the car, the return it to the main landing site, opening and holding in the open position of the cabin and shaft doors.

4.1.9.2 Passenger elevators intended for the transportation of fire brigades must have a mode of operation "transportation of fire brigades". The transfer of the elevator control to this mode should be carried out from the cabin, while the control system should ensure the operation of the elevator only by orders from the cabin.

4.1.10 The cladding of the compartment compartment, shades, flooring, as well as buttons for orders and call stations should be made of non-combustible or hardly combustible materials.

4.1.11 In the roof of the elevator car used for the transportation of fire brigades, a hatch with a size of at least 700 x 500 mm must be provided. The hatch must be equipped with a switch that controls its locking.

4.1.12 Doors of the elevator shaft must be fireproof of the second type and comply with the requirements of SNiP 2.01.02 (sections 3 and 4).

The fire resistance limit of the doors of the passenger elevator shaft for residential buildings with a speed of up to 1.0 m / s inclusive is not established.

The doors of the cargo elevator shaft may not be equipped with a self-closing device.

Freight small elevators with two stops are allowed to be executed in a metal-frame shaft with a fence made of metal sheets. At the same time, fire-prevention requirements are not imposed on the shaft doors.

4.1.1H. The system of electric drive and automation of elevators should provide the ability to connect external systems for monitoring the operation of the elevator and identifying its faults.

Requirements for elevator control and signaling devices are in accordance with GOST 28911. When installing a group of two or more passenger elevators with the same rated speed and, as a rule, the number of stops, a group control system with a common control ringing device should be used at each landing site.

4.1.14 Signal colors and safety signs - in accordance with GOST 12.4.026 and GOST 28911, respectively.

Wherein:

The surfaces of grease fittings, caps, drain plugs, oil indicators should be coated with a red color;

The surfaces of the rotating parts, not covered by the casing, except for the surfaces of the rotating parts on the rope tensioner of the speed limiter and the counterweight, must have a yellow coating.

It is allowed to paint the end surfaces of parts of rotation in the form of an annular strip with a width of at least 20 mm in accordance with the indication of the place of painting on the drawings.

Passenger elevators with a mode of operation "transportation of fire brigades" must have distinctive symbols located on the main landing site, in accordance with the instructions in the design documentation.

4.1.15 Technical documentation for the elevator must comply with the requirements of the design of the elevator project, approved in the prescribed manner.

4.1.16 The paint and varnish coatings of the surfaces of the lift equipment must comply with the coating classes specified in Table 5.

Table 5

Surface name with paintwork Coating class according to GOST 9.032
The surfaces of the elevator components located in the shaft, machine room and block room, including:VI
- outer surfaces of cab fencing (shields);
- non-face surfaces of the doors of the cab and shaft doors;
- guides of the cab and counterweight, except for the working surface of the head of the T-profile guides;
- details (except for fasteners) and assembly units for fastening car rails and counterweight;
- surfaces of the cabin frame and counterweight, brackets for fastening shunts and sensors in the mine and on the cabin, metal structures for installing blocks, buffers, tensioning devices, transformers and other electrical equipment, frame and subframes of the winch;
- untreated surfaces of blocks and pulleys, grounding bus;
- cast iron weights of counterweight and rope tensioner, speed limiter
The inner surfaces of the passenger elevator car, not visible from the inside. The inner surfaces of the freight elevator car, visible from the inside.V
Untreated surfaces of gearbox, handwheel, winch brake, speed limiter, hydraulic buffer
The inner surfaces of the passenger elevator car, visible from the inside.IV, III
(at the request of the customer)
The front surfaces of the doors of the cab and shaft doors, if they do not have another decorative finish

Metal coatings must comply with GOST 9.301. Equipment for tropical climatic elevators is painted in accordance with GOST 9-401.

4.1.17 The equipment of the freight elevator, as agreed with the customer, is allowed to be coated with a primer followed by painting after installation.

Lack of coloring in hard-to-reach places is allowed.

Hard-to-reach places should be indicated in the design documentation.

It is allowed not to cover the cast iron weights of the counterweight and the tensioner of the elevator speed limiter.

4.1.18 The front side of the shaft door leaves of one or more elevators must have a coating at each stopping site

one color and one shade, if there is no other requirement of the customer.

4.1.19 The places of welding (welded seams and heat-affected surfaces) made during the installation of the elevator must be protected by the coating provided for them in the technical documentation for the elevator.

4.1.20 Ropes should be of measured length from one coil and with a cleaned surface. Dirt and other inclusions on the surface of the ropes are not allowed.

The ends of the ropes must be protected from unwinding, and at the cut-off point they must be made in accordance with 2.1.9 GOST 3241.

4.1.21 The overhead electric cable of the elevator must be cut, with terminated and marked wires.

Wiring harnesses throughout the mine and machine room must be labeled. By agreement with the customer, delivery of measured length wires is allowed.

4.1.22 Requirements for welded assembly units, castings from ferrous metals, aluminum and high tin bronze, parts made of plastic materials, machined parts, heat treatment, as well as requirements for components of elevators - according to the normative and technical documentation (NTD) applicable to them ...

4.2 Completeness

4.2.1 The lift kit should include:

Elevator equipment in accordance with the elevator specification, incl. spare parts and materials designed for the warranty period of the lift, tools and accessories (spare parts) required for maintenance and repair of the lift; spare parts for commissioning during installation (ZIM) in accordance with their lists;

Technical documentation sent with the lift, and the List of replacement parts in accordance with Appendices B and C, respectively.

In the case of sending several elevators of the same type, type, carrying capacity, speed and performance (different location of the counterweight, passable or non-passable car, etc.) for installation at one facility or building, the technical documentation is sent in one copy for 5 elevators. Passport, electrical circuit diagram, electrical connection diagram, installation (installation) drawing should be sent with each elevator,

4.2.2 Components of the elevator: winch, cabin, shaft doors, hydraulic buffer, speed limiter, tensioner

should be sent assembled and adjusted, unless otherwise requested by the customer.

Mounting brackets for floor switches, shunts, selection sensors, floor terminal boxes should be shipped with clamps attached. Rail fastening parts should be sent assembled with clamps attached.

4.2.3 Disassembled, it is allowed to send:

Counterweight;

Freight elevator cabin with dimensions in terms of 1500 x 2000 mm and more;

Hospital elevator cabin for buildings of medical and preventive institutions;

Freight lift shaft doors with an opening width of more than 2000 mm or a height of more than 2600 mm;

Framing (if any) of the openings of the mine doors of passenger elevators.

4.3 Marking

4.3.1 Each lift must be provided with a plate made in accordance with GOST 12969, GOST 12970 and GOST 12971.

The elevator plate must indicate:

The name or trademark of the lift manufacturer; -type of elevator (according to GOST 5746, GOST 8823, GOST 8824)<*>, lift index, climatic version, location category;

<*>Without specifying the word "electric".

Carrying capacity and capacity of the cabin (for elevators in which the transportation of people is allowed);

Serial number, month and year of manufacture of the elevator.

4.3.2 Marking of packages should be done in accordance with GOST 14192.

Marking of lift equipment packages for the Far North of the Russian Federation and hard-to-reach areas (for example, mountainous, etc.) - in accordance with GOST 15846.

4.4 Packaging

4.4.1 The components of the elevator equipment must be preserved before packing.

Temporary anti-corrosion protection - in accordance with GOST 9.014.

The use of conservation oils for the preservation of ropes is not allowed. They can be used to cover the surface of the T-profile guides.

Preservation of the components of the elevator equipment should ensure their protection until the first re-preservation: the components of the elevator - up to one year, spare parts - up to 2.5 years. Re-preservation must be carried out by the owner of the lift.

The packing lists must indicate: the date and period of re-preservation, as well as the means of temporary corrosion protection.

4.4.2 Preservation and packaging of wires and cables should be carried out taking into account the requirements of GOST 18690, electrical equipment (including harnesses) - in accordance with GOST 23216.

4.4.3 Packing of equipment and technical documentation of the elevator - in accordance with GOST 23170.

Ropes are packed in a polymer film in accordance with GOST 10354 or other NTD agreed with Gosgortekhnadzor<*>or in waterproof paper according to GOST 8828, GOST 515.

A rope wound into a coil must be tightly tied with soft wire (in accordance with GOST 3282 or other NTD) or a strand of the same rope, or with a tape in accordance with GOST 3560 (or other NTD) in at least 4 places evenly spaced around the circumference.

4.4.4 Packaging of lift equipment in a tropical climatic version must comply with the requirements of GOST 24634, while the timber for packaging must be impregnated with an antiseptic. Instead of antiseptic treatment, it is allowed to paint boxes in two layers with PF-115 gray paint in accordance with GOST 6465 or other similar paints,

4.4.5 Packing of elevator equipment sent to the Far North of the Russian Federation and hard-to-reach areas - in accordance with GOST 15846.

5. SAFETY REQUIREMENTS

The safety of elevators is ensured by meeting the set of requirements 4.1.1 - 4J.22 (except 4.1.15, 4.1.17 - 4.1.18, 4.1.21), sections 3, 5 - 7, 9 of this standard and PUBEL Gosgortechnadzor.

6. RULES OF ACCEPTANCE

6.1 Component parts (equipment) of the elevator (including spare parts and accessories, ZIM) must be subjected to acceptance control by the manufacturer's technical control service in order to determine their suitability for shipment to the consumer.

6.2 Acceptance control of the components of the elevator must be statistical on an alternative basis in accordance with GOST 18242.

Parameters, dimensions, requirements to be controlled, sample size and types of defects must be indicated in the technical documentation for the elevator.

6.3 Acceptance inspection of the components of the elevator must have the following inspection plan and the acceptance level of defectiveness:

a) alan control:

Control level - II,

Control plan type - one-stage,

Control type - according to GOST 18242;

b) the acceptance level of defectiveness of the winch, gearbox (if it is produced as a spare part), elevator door drive, speed limiter, safety devices, hydraulic buffer, cabin loading control device, shaft doors, cabin doors, critical springs (buffer springs, brakes, safety , cab hangers and counterweight, etc.) and spare parts, ZIM:

2.5% for significant defects;

6.5% for minor defects.

Acceptance level of defectiveness of other assembly units and equipment parts:

0% - for critical defects;

6.5% for significant defects.

The production cycle under continuous statistical control is 1 year.

6.4 Purchased products, materials and raw materials should be subject to incoming inspection in accordance with GOST 24297.

During the incoming inspection, the low-voltage complete device (ASSEMBLY) must be checked for functioning.

When the customer or the consumer of the elevators receives complaints or claims to the quality of the purchased product, the manufacturer of the elevator during the incoming inspection must use another more stringent type of control in accordance with GOST 18242.

6.5 Elevator components, parts and castings produced by other manufacturers must be visually inspected by the elevator manufacturer to detect possible damage to this equipment during transportation.

The manufacturer of equipment, parts and castings, upon receipt of claims from the manufacturer of the elevator, must within 3 days. inform him about the decision taken to eliminate the defect.

6.6 Acceptance tests of the components - (equipment) of the elevator

The components of the lift referred to in 6.3 must be subjected to acceptance tests by its manufacturer according to programs and procedures approved in the prescribed manner.

The sampling volume of samples of the elevator components is set by the elevator manufacturer and is indicated in the technical documentation.

6.7 Elevators of each model must be tested:

After making a prototype:

Preliminary;

Acceptance;

When mastering production - qualification;

For serial production:

Acceptance tests of the elevator components;

Periodic;

Typical.

6.8 The frequency of the elevator tests specified in 6.7, the number of elevators that should be subjected to these tests, and the number of elevators in the batch from which the elevator is selected for testing shall be in accordance with table 6,

6.9 Periodic testing

6.9.1 Periodic tests of the elevator are carried out in order to check the stability of the workmanship and the possibility of continuing its release.

Periodic tests should include verification of all mandatory requirements established by this standard and PUBEL Gosgortekhnadzor.

6.9.2 In case of unsatisfactory results of periodic tests at least one of the points of the program, repeated tests should be carried out on these points on a double number of the corresponding components of the lift, taken from the same batch. Retest results are final.

Table 6

Test typeFrequency of testsNumber of liftsThe number of lifts in the batch from which the lifts are selected for testing
PreliminaryOne-time - after making prototypesAll prototypes of the elevator, the number of which is determined by the terms of reference for the development
ReceivingToo1 All pre-tested prototypes
QualifyingWhen launching an elevator of this model1 Not less than 3
PeriodicAt least once every 3 years1 Not less than 7<*>
TypicalWith every design change1 Not less than 3

<*>When carrying out tests at the manufacturer, the elevators are selected from among those that have passed the acceptance control and are ready for shipment to the consumer. When conducting tests at the operating facility, they are selected from the number of manufactured items no more than 18 months before the start of tests.

7. CONTROL METHODS

7.1 Requirements for measuring instruments

7.1.1 Measuring instruments shall be checked in accordance with the requirements of GOST 8.002 and GOST 8.513.

Test equipment must be certified in accordance with GOST 24555, non-standardized measuring instruments must pass metrological certification in accordance with GOST 8.326.

7.2 Test preparation

7.2.1 Prior to the acceptance and qualification tests of the elevator, tests for the reliability of the winch, drive of doors, car doors, shaft doors, speed limiters, safety devices, hydraulic buffers, and car loading control devices must be performed.

It is allowed not to carry out tests for the reliability of equipment borrowed from other elevators, provided that it has been tested earlier and the manufacturer has a justification for maintaining the reliability indicators under operating conditions.

A low-voltage complete device must have a document confirming its reliability.

7.2.2 Before carrying out periodic tests, the manufacturer must provide materials confirming the reliability indicators of the elevators.

Confirmation of reliability indicators is carried out on the basis of a test for the reliability of an elevator or its components (equipment) in the period between periodic tests or on the basis of the results of operational observations of the operation of similar elevators.

Methods and plans of tests for reliability and observations during operation - in accordance with GOST 27.410.

7.2.3 To conduct type tests of an elevator, in which equipment is used with changes that can affect the technical characteristics of the elevator and / or its operation, tests should be carried out for each changed equipment.

If the test results of the modified equipment are positive, it is allowed to carry out type tests of the elevator.

7.3 Carrying out elevator tests

7.3.1 Tests of elevators should be carried out in accordance with the Programs and test methods agreed in the prescribed manner.

7.3.1.1 Before testing the lift, the manufacturer must have a "Certificate of technical readiness for the lift".

The tests must be carried out on the premises of the lift manufacturer. Carrying out tests of the elevator at the operation site must be agreed with the Gosgortekhnadzor.

It is not allowed to replace the tests of the elevator by testing its layout.

When testing group control of elevators with three or more elevators in a group, it is allowed to simulate this system.

When testing several elevators of the same type and type, it is allowed to determine the quantitative and qualitative characteristics of one elevator - a typical representative of the group (determined by the elevator developer). For the rest of the elevators in the group, characteristics that differ from the characteristics of the typical representative must be checked.

In case of unsatisfactory test results for one or several indicators, the resumption of repeated tests is allowed only after the causes of the deficiencies are established and their elimination.

8. TRANSPORTATION AND STORAGE

8.1 Transportation of elevator equipment is allowed to be carried out by any type of transport in accordance with the transportation rules applicable to them.

When transporting elevator equipment on ship decks, the elevator manufacturer must take into account the effect of the type III atmosphere in accordance with GOST 15150.

8.2 Conditions and terms of storage and transportation of elevator equipment, spare parts and accessories in the packaging and (or) preservation of the manufacturer must correspond to those indicated in Table 7.

Table 7

Climatic version of the elevator in accordance with GOST 15150Elevator equipment
mechanical with installed electrical equipmentmechanical without electrical equipmentSPTA and ZIM
Storage conditions according to GOST 15150, section 10
UHL2 5 2
THEN3 6 3
Shelf life, month, no more
UHL, T, O21 21 57
Transportation conditions according to GOST 15150, section 10
UHL8 8 8
THEN9 9 9
Transportation period, month, no more
UHL.T, O3 3 3

It is allowed to store elevator equipment under storage conditions 8 in accordance with GOST 15150 both at the manufacturer and at the customer for 3 months with a total storage period of no more than 6 months.

9. INSTRUCTIONS FOR INSTALLATION AND USE

9.1 Installation of elevators should be carried out in accordance with the requirements of GOST 22845, PUBEL and technical documentation for the installation of the elevator.

9.2 The operation of the elevators must be carried out in accordance with the requirements of PUBEL and the operating instructions.

5 6 7 8

1 - type of elevator; LP - passenger elevator with basic parameters and design in accordance with GOST 5746;

2 - group of conventional designation of the main parameters of the elevator (carrying capacity and rated speed), set in accordance with the methodology in force in the elevator industry of the CIS countries;

3 - an indication of the installation of an elevator - single (do not indicate in the symbol), group (G) from group 2 - 4, 6 elevators (G2 - G4, G6);

4- the number of stops of the elevator;

6 - an indication of the execution of the elevator (execution without taking into account the seismic effect in the symbol is not indicated), taking into account the seismic effect (C) with an intensity of 7 - 9 points (C7 - C9);

7- indication of the presence of the elevator operating mode "transportation of fire brigades" (P);

8- designation of this standard.

An example of a symbolic designation of a passenger elevator for residential buildings with the main dimensions and design according to GOST 5746, with a carrying capacity of 400 kg, with a nominal speed of 0.71 m / s, a single installation, with 10 stops, in a version for operation in a moderately cold climate zone , placement categories 4 and in an area with an intensity of seismic impact of 8 points, which does not have a mode of operation "transportation of fire brigades":

LP 0471 10 UHL4 S8 GOST 22011-95

Appendix B. LIST OF TECHNICAL DOCUMENTATION SET

<*>Depending on the type and type of a particular elevator, the list of documents for its equipment is specified by the developer.

The set of technical documentation for the elevator includes the following documents:

Elevator passport according to PUBEL Gosgortekhnadzor with documents certifying the quality: winches, speed limiter, door drive, hydraulic buffer, cabin buffer springs and counterweight, brake springs, safety springs. NKU passport (stored together with the elevator passport);

Installation drawing (installation drawing, a sample of which has been approved by Gosgortekhnadzor) (2 copies);

Instructions for installation, start-up, regulation and running-in;

Technical description and operating instructions;

Basic electrical diagram with a list of elements (3 copies);

Description of the electric drive and automation (it is allowed to supply as part of the technical description and operating instructions);

Traction pulley.

Brake shoe assembly.

Brake spring.

Cab slip shoe liner.

Cab shoe roller (s).

Sliding door insert for freight elevators.

Shoe for doors of passenger elevators.

Roller for the doors of freight elevators.

Roller for carriages of passenger elevator cabin doors.

Roller drove drive doors of passenger elevators.

Rubber stop for the drive of the cab doors.

Counterweight sliding shoe bushing.

Roller carriages of automatic sliding doors of the mine.

Roller rubberized for the lock of the doors of the mine.

Speed ​​limiter pulley.

Elevator traction rope outlet block.

V-belt drive pulleys of the cab door drive.

Rubber ring of the device for controlling the loading of the moving field of the cab.

Cab door drive belt.

Note - The list of details is specified for a specific elevator by its developer.

The site "Zakonbase" presents "PASSENGER AND FREIGHT ELEVATORS. TECHNICAL CONDITIONS. GOST 22011-95" (approved by the State Standard of the Russian Federation) in the latest edition. It is easy to comply with all legal requirements if you read the relevant sections, chapters and articles of this document for 2014. To search for the necessary legislative acts on a topic of interest, you should use the convenient navigation or advanced search.

On the Zakonbase website you will find "PASSENGER AND FREIGHT ELEVATORS. TECHNICAL CONDITIONS. GOST 22011-95" (approved by the State Standard of the Russian Federation) in a fresh and complete version, in which all changes and amendments have been introduced. This guarantees the relevance and reliability of the information.

At the same time, you can download "PASSENGER AND FREIGHT ELEVATORS. TECHNICAL CONDITIONS. GOST 22011-95" (approved by the State Standard of the Russian Federation) completely free of charge, both in full and in separate chapters.

GOST 22011-95

INTERSTATE STANDARD

PASSENGER ELEVATORS
AND CARGO

TECHNICAL CONDITIONS

INTERSTATE COUNCIL
FOR STANDARDIZATION, METROLOGY AND CERTIFICATION

Minsk

1998 year

Foreword

1 DEVELOPED TC 209 "Elevators and construction hoists"

INTRODUCED by the State Standard of Russia

2 ADOPTED by the Interstate Council for Standardization, Metrology and Certification (Protocol No. 8-95 of October 12, 1995)

State name

Name of the national standardization body

The Republic of Azerbaijan

Azgosstandart

Republic of Belarus

Belstandard

The Republic of Kazakhstan

Gosstandart of the Republic of Kazakhstan

Kyrgyz Republic

Kyrgyzstandart

The Republic of Moldova

Moldovastandart

Russian Federation

Gosstandart of Russia

The Republic of Tajikistan

Tajik State Center for Standardization, Metrology and Certification

Turkmenistan

Main State Inspectorate of Turkmenistan

The Republic of Uzbekistan

Uzgosstandart

State Standard of Ukraine

3 By the Resolution of the Committee of the Russian Federation for Standardization, Metrology and Certification No. 68 dated February 15, 1996, the interstate standard 22011-95 was put into effect directly as a state standard of the Russian Federation from January 1, 1997.

4 REPLACE GOST 22011-90

5 REVISION

INTERSTATE STANDARD

PASSENGER AND FREIGHT ELEVATORS

Technical conditions

Passenger and goods lifts. Specifications

Date of introduction 1997-01-01

1 AREA OF USE

This standard applies to electric passenger, hospital, freight and small freight elevators (hereinafter referred to as elevators).

The standard does not apply to elevators:

Freight sidewalk;

Ship;

Special purpose;

For work in buildings and premises classified into categories A and B * for explosion and fire hazard;

For work in rooms with corrosive vapors or gases;

For operation in conditions of condensation in a mine or machine room, frost or ice formation on equipment.

* Categories of buildings and premises for explosion and fire hazard are determined at the design stage of buildings and structures in accordance with the requirements of national standards in the field of fire hazard.

The requirements of this standard are mandatory.

Mandatory requirements for the quality of elevators, ensuring their safety for life, health and property of the population, environmental protection, are set out in section 5.

2 REFERENCES

GOST 8.002-86 GSI. State supervision and departmental control over measuring instruments. Basic Provisions

GOST 8.326-89 GSI. Metrological certification of measuring instruments

GOST 8.513-84 GSI. Verification of measuring instruments. Organization and procedure

GOST 9.014-78 ESZKS. Temporary anti-corrosion protection of products. General requirements

GOST 9.032-74 ESZKS. Paint and varnish coatings. Groups, technical requirements and designations

GOST 9.301-86 ESZKS. Metallic and non-metallic inorganic coatings. General requirements

GOST 9.401-91 ESZKS. Paint and varnish coatings. General requirements and methods of accelerated tests for resistance to climatic factors

GOST 12.4.026-76 SSBT. Signal colors and safety signs

GOST 27.410-87 Reliability in technology. Reliability Methods and Reliability Proof Test Plans

GOST 515-77 Bituminous and tar packing paper. Technical conditions

GOST 3241-91 Steel ropes. Technical conditions

GOST 3282-74 Low-carbon steel wire for general use. Technical conditions

GOST 3560-73 Steel packing tape. Technical conditions

GOST 5746-83 Electric passenger lifts. Basic parameters and dimensions

GOST 6465-76 Enamels PF-115. Technical conditions

GOST 8823-85 Electric freight elevators. Basic parameters and dimensions

GOST 8824-84 Small electric freight elevators. Basic parameters and dimensions

GOST 8828-89 Base paper and two-layer waterproof packaging paper. Technical conditions

GOST 10354-82 Polyethylene film. Technical conditions

GOST 12969-67 Plates for machines and devices. Technical requirements

GOST 12970-67 Round plates for machines and devices. Dimensions (edit)

GOST 12971-67 Rectangular plates for machines and devices. Dimensions (edit)

GOST 14192-96 Marking of goods

GOST 15150-69 Machines, devices and other technical products. Versions for different climatic regions. Categories, operating conditions, storage and transportation in terms of the impact of climatic environmental factors

GOST 15846-79 Products sent to the Far North and hard-to-reach areas. Packaging, labeling, transportation and storage

GOST 18242-72 Statistical acceptance control on an alternative basis. Control plans

GOST 18690-82 Cables, wires, cords and cable accessories. Marking, packaging, transportation and storage

GOST 22845-85 Electric passenger and cargo lifts. Rules for the organization, production and acceptance of installation work

GOST 23170-78 Packaging for mechanical engineering products. General requirements

GOST 23216-78 Electrical products. General requirements for storage, transportation, temporary corrosion protection and packaging

GOST 23511-79 Industrial radio interference from electrical devices used in residential buildings or connected to their electrical networks. Norms and methods of measurements

GOST 24297-87 Incoming control of products. Basic Provisions

GOST 24555-81 SGIP. The procedure for the certification of test equipment. Basic Provisions

GOST 24634-81 Wooden boxes for products supplied for export. General specifications

GOST 28911-91 Elevators and small freight elevators. Control devices, alarms and additional devices

"Rules for the construction and safe operation of elevators" of the national bodies of technical supervision for the safe operation of elevators

SNiP 21-01-97 Building norms and rules. Fire safety of buildings and structures

3 BASIC PARAMETERS AND DIMENSIONS

The main parameters and dimensions of electric passenger and hospital elevators are in accordance with GOST 5746.

The main parameters and dimensions of electric freight elevators are in accordance with GOST 8823.

The main parameters and dimensions of electric freight small elevators are in accordance with GOST 8824.

The designation of the elevators is given in Appendix A.


page 1



page 2



p. 3



page 4



p. 5



page 6



page 7



page 8



page 9



p. 10



page 11



p. 12



p. 13



page 14



p. 15



page 16



p. 17



p. 18



p. 19



page 20



p. 21



page 22



page 23



page 24



p. 25



p. 26



page 27



page 28

INTERSTATE STANDARD

PASSENGER ELEVATORS
AND CARGO

TECHNICAL CONDITIONS

INTERSTATE COUNCIL
FOR STANDARDIZATION, METROLOGY AND CERTIFICATION
Minsk

Foreword

1 DEVELOPED TC 209 "Elevators and construction hoists"

INTRODUCED by the State Standard of Russia

2 ADOPTED by the Interstate Council for Standardization, Metrology and Certification (Protocol No. 8-95 of October 12, 1995)

State name

Name of the national standardization body

The Republic of Azerbaijan

Azgosstandart

Republic of Belarus

Belstandard

The Republic of Kazakhstan

Gosstandart of the Republic of Kazakhstan

Kyrgyz Republic

Kyrgyzstandart

The Republic of Moldova

Moldovastandart

Russian Federation

Gosstandart of Russia

The Republic of Tajikistan

Tajik State Center for Standardization, Metrology and Certification

Turkmenistan

Main State Inspectorate of Turkmenistan

The Republic of Uzbekistan

Uzgosstandart

State Standard of Ukraine

3 By the Resolution of the Committee of the Russian Federation for Standardization, Metrology and Certification No. 68 dated February 15, 1996, the interstate standard 22011-95 was put into effect directly as a state standard of the Russian Federation from January 1, 1997.

5 REVISION

PASSENGER AND FREIGHT ELEVATORS

Technical conditions

Passenger and goods lifts. Specifications

Date of introduction 1997-01-01

1 AREA OF USE

This standard applies to electric passenger, hospital, freight and small freight elevators (hereinafter referred to as elevators).

The standard does not apply to elevators:

Freight sidewalk;

Ship;

Special purpose;

For work in buildings and premises classified into categories A and B * for explosion and fire hazard;

For work in rooms with corrosive vapors or gases;

For operation in conditions of condensation in a mine or machine room, frost or ice formation on equipment.

* Categories of buildings and premises for explosion and fire hazard are determined at the design stage of buildings and structures in accordance with the requirements of national standards in the field of fire hazard.

The requirements of this standard are mandatory.

Mandatory requirements for the quality of elevators, ensuring their safety for life, health and property of the population, environmental protection, are set out in section 5.

2 REFERENCES

The main parameters and dimensions of electric freight elevators are in accordance with GOST 8823.

The main parameters and dimensions of electric freight small elevators are in accordance with GOST 8824.

The designation of the elevators is given in Appendix A.

4 TECHNICAL REQUIREMENTS

4.1 Features

4.1.1 Elevators must meet or exceed the requirements of this standard, the "Rules for the Construction and Safe Operation of Elevators" of the national technical supervision bodies for the safe operation of elevators (hereinafter - PUBEL Gosgortechnadzor) and the "Rules for Electrical Installation" of the Ministry of Fuel and Energy.

4.1.2 The installation of elevators for work in buildings and premises classified by explosion and fire hazard category B should be carried out in accordance with the requirements of national building codes and regulations for lifts of this category.

4.1.3 Installation of elevators in buildings and structures located in areas with a seismic impact of 7-9 points is allowed if the requirements that take into account the operating conditions specified in the regulatory or design documentation are met.

4.1.4 The values ​​of the parameters of the lifts must correspond to those given in Tables 1 and 2.

4.1.5 Lifts must operate in the operating modes specified in Table 3, and maintain a working condition at an altitude of up to 2000 m above sea level.

When the elevator is operated at an altitude of 1000 to 2000 m, the number of starts per hour is reduced by 1% for every 100 m.

4.1.6 Elevators are made to operate from an alternating current with a frequency of 50 Hz and a voltage of 380 V.

Table 1

Indicator name

Passenger elevators

for residential buildings

for public buildings and industrial buildings

for industrial buildings

sick leave

Rated speed, m / s

Assigned service life, years

Accuracy of stopping the elevator car, mm, with a drive:

Adjustable

Unregulated

A, no more

Sound level in the cab when opening and closing doors, dB A, no more

Vibration speed of the cabin floor with steady motion, m / s, no more

Corrected winch sound power level, dB A, not less

Carrying capacity, kg

800; 1000; 1250; 1600

Note - At the end of the designated lifespan of the elevator, it is inspected in accordance with the procedure established by Gosgortekhnadzor.

table 2

Indicator name

Freight elevators

Rated speed, m / s

Mean time between failures, h, not less

Assigned service life, years

Sound level in the cab with steady motion, dB A, no more

Vibration speed, m / s, no more

Corrected winch sound power level, dB A, no more

Carrying capacity, kg

2000 and more

* For elevators with a lifting capacity of 5000 kg.

** For lifts with a lifting capacity of 4000 and 6300 kg.

Note - At the end of the designated lifespan of the elevator, it is inspected in accordance with the procedure established by Gosgortekhnadzor.

Table 3

Rated speed, m / s

Working hours

Number of starts per hour, no more

Relative duration of PV activation,%, no more

Passenger

for residential buildings

for buildings of public and industrial enterprises

sick leave

for industrial buildings

Cargo

clutch release, with monorail

Cargo small

* For lifts with a lifting capacity of St. 630 kg

Table 4

Climatic version

Limiting operating temperatures, ° С

Upper value of relative air humidity

machine room

Passenger

for residential buildings, buildings of public and industrial enterprises, hospital

+40 to +1

80% at + 25 ° С

80% "+ 25 ° C

+55 to +1

98% at + 35 ° С

98% "+ 35 ° C

for industrial buildings

+40 to -40

98 % at + 25 ° С

80% "+ 25 ° C

Cargo

normal, clutch release, with monorail

+40 to -20

98% at + 25 ° С

98% "+ 25 ° C

+45 to -10

98% at + 35 ° С

98% "+ 35 ° C

Cargo small

+40 to +1

80% at + 25 ° С

* When recording the climatic performance of the elevator, the category of its placement is indicated by the category of the location of the machine room.

At the request of the customer, elevators can be manufactured for operation from the alternating current network:

Frequency 50 Hz with voltage 240 and 415 V;

Frequency 60 Hz "220; 230; 380; 400; 415 and 440 V.

Elevators must be operational when connected to an alternating current network with deviations from their rated values ​​of current frequency of no more than 1% and voltage of no more than 10%.

4.1.7 Radio interference arising from the operation of the elevator should not exceed the values ​​established by GOST 23511 and national standards for permissible industrial radio interference. The field strength of the radio interference generated by the elevator is not standardized.

4.1.8 Elevators, depending on the operating conditions, should be made of climatic versions and placement categories (according to GOST 15150), shown in Table 4.

4.1.9 Cabins of freight elevators with solid doors, except for externally controlled elevators, as well as passenger elevators for residential and public buildings and industrial buildings must have natural ventilation.

The cabins of passenger, hospital and freight elevators (with a conductor) with solid doors in tropical design must have natural and forced ventilation.

4.1.9.1 Passenger elevators with automatic doors at a speed of 1.0 m / s and more must have a "fire hazard" operating mode, which is activated by a signal from the building's automatic fire alarm systems and provides, regardless of the load and the direction of movement of the car, the return it to the main landing site, opening and holding open the doors of the cabin and the shaft.

4.1.9.2 Passenger elevators intended for the transportation of fire brigades must have a mode of operation "transportation of fire brigades". The transfer of the elevator control to this mode should be carried out from the cabin, while the control system should ensure the operation of the elevator only by orders from the cabin.

4.1.10 The cladding of the compartment compartment, shades, flooring, as well as buttons for orders and call stations should be made of non-combustible or hardly combustible materials.

4.1.11 In the roof of the elevator car used for the transportation of fire departments, a hatch with a size of at least 700x500 mm must be provided. The hatch must be equipped with a switch that controls its locking.

4.1.12 Doors of the elevator shaft must be fireproof of the second type and comply with the requirements of SNiP 21-01 (sections 3 and 4).

The fire resistance limit of the doors of the passenger elevator shaft for residential buildings with a speed of up to 1.0 m / s inclusive. not installed.

The doors of the cargo elevator shaft may not be equipped with a self-closing device.

Small freight elevators with two stops are allowed to be performed in a metal-frame shaft with a fence made of metal sheets. At the same time, fire safety requirements are not imposed on shaft doors.

4.1.13. The system of electric drive and automation of elevators should provide the ability to connect external systems for monitoring the operation of the elevator and identifying its faults.

Requirements for elevator control and signaling devices are in accordance with GOST 28911. When installing a group of two or more passenger elevators with the same rated speed and, as a rule, the number of stops, a group control system with a common control ringing device should be used at each landing site.

4.1.14 Signal colors and safety signs - in accordance with GOST 12.4.026 and GOST 28911, respectively.

Wherein:

The surfaces of grease fittings, caps, drain plugs, oil indicators should be coated with a red color;

The surfaces of the rotating parts, not covered by the casing, except for the surfaces of the rotating parts on the rope tensioner of the speed limiter and the counterweight, must have a yellow coating.

It is allowed to paint the end surfaces of parts of rotation in the form of an annular strip with a width of at least 20 mm in accordance with the indication of the place of painting on the drawings.

Passenger elevators with a mode of operation "transportation of fire brigades" must have distinctive symbols located on the main landing site, in accordance with the instructions of the design documentation.

4.1.15 Technical documentation for the elevator must comply with the requirements of the elevator design project, approved in the prescribed manner.

4.1.16 The paint and varnish coatings of the surfaces of the lift equipment must comply with the coating classes specified in Table 5.

Table 5

Name of the surface with a paint-and-lacquer coating

The surfaces of the elevator components located in the shaft, machine room and block room, including:

Outer surfaces of cab fencing (shields);

Non-front surfaces of the doors of the cab and shaft doors;

Guides for the cab and counterweight, except for the working surface of the head of the T-profile guides;

Details (except for fasteners) and assembly units for fastening car rails and counterweight;

Surfaces of the cabin frame and counterweight, brackets for fastening shunts and sensors in the mine and on the cabin, metal structures for installing blocks, buffers, tensioning devices, transformers and other electrical equipment, frame and subframes of the winch;

Untreated surfaces of blocks and pulleys, grounding bars;

Cast iron counterweight and rope tensioner weights, speed limiter

The inner surfaces of the passenger elevator car, not visible from the inside. The inner surfaces of the freight elevator car, visible from the inside.

Untreated surfaces of gearbox, handwheel, winch brake, speed limiter, hydraulic buffer

The inner surfaces of the passenger elevator car, visible from the inside.

The front surfaces of the doors of the cab and shaft doors, if they do not have another decorative finish

IV, III (at the request of the customer)

Metal coatings must comply with GOST 9.301. Equipment for tropical climatic elevators is painted in accordance with GOST 9.401.

4.1.17 The equipment of the freight elevator, as agreed with the customer, is allowed to be coated with a primer followed by painting after installation.

Lack of coloring in hard-to-reach places is allowed.

Hard-to-reach places should be indicated in the design documentation.

It is allowed not to cover the cast iron weights of the counterweight and the tensioner of the elevator speed limiter.

4.1.18 The front side of the shaft door leaves of one or more elevators must have a coating of one color and one shade at each stopping site, unless otherwise requested by the customer.

4.1.19 The places of welding (welded seams and heat-affected surfaces) made during the installation of the elevator must be protected by the coating provided for them in the technical documentation for the elevator.

4.1.20 Ropes should be of measured length from one coil and with a cleaned surface. Dirt and other inclusions on the surface of the ropes are not allowed.

The ends of the ropes must be protected from unwinding, and at the cut-off point they must be made in accordance with 2.1.9 GOST 3241.

4.1.21 The overhead electric cable of the elevator must be cut, with terminated and marked wires.

Wiring harnesses throughout the mine and machine room must be labeled. By agreement with the customer, delivery of measured length wires is allowed.

4.1.22 Requirements for welded assembly units, castings from ferrous metals, aluminum and high tin bronze, parts made of plastic materials, machined parts, heat treatment, as well as requirements for components of elevators - according to the normative and technical documentation (NTD) applicable to them ...

4.2 Completeness

4.2.1 The lift kit should include:

Elevator equipment in accordance with the elevator specification, incl. spare parts and materials designed for the warranty period of the lift, tools and accessories (spare parts) required for maintenance and repair of the lift; spare parts for commissioning during installation (ZIM) in accordance with their lists;

Technical documentation sent with the lift, and the List of replacement parts in accordance with Appendices B and C, respectively.

In the case of sending several elevators of the same type, type, carrying capacity, speed and performance (different location of the counterweight, passable or non-passable car, etc.) for installation at one facility or building, the technical documentation is sent in one copy for 5 elevators. Passport, electrical circuit diagram, electrical connection diagram, installation (installation) drawing should be sent with each lift.

4.2.2 The components of the elevator: winch, cabin, shaft doors, hydraulic buffer, speed limiter, tensioner should be sent assembled and adjusted, unless otherwise requested by the customer.

Mounting brackets for floor switches, shunts, selection sensors, floor terminal boxes should be shipped with clamps attached. Rail fastening parts should be sent assembled with clamps attached.

4.2.3 Disassembled, it is allowed to send:

Counterweight;

Freight elevator cabin with dimensions in terms of 1500x2000 mm and more;

Hospital elevator cabin for buildings of medical and preventive institutions;

Freight lift shaft doors with an opening width of more than 2000 mm or a height of more than 2600 mm;

Framing (if any) of the openings of the mine doors of passenger elevators.

4.3 Marking

4.3.1 Each lift must be provided with a plate made in accordance with GOST 12969, GOST 12970 and GOST 12971.

The elevator plate must indicate:

The name or trademark of the lift manufacturer;

Marking of lift equipment packages for the Far North of the Russian Federation and hard-to-reach areas (for example, mountainous, etc.) - in accordance with GOST 15846.

4.4 Packaging

4.4.1 The components of the elevator equipment must be preserved before packing.

Temporary anti-corrosion protection - in accordance with GOST 9.014.

The use of conservation oils for the preservation of ropes is not allowed. They can be used to cover the surface of the T-profile guides.

Preservation of the components of the elevator equipment should ensure their protection until the first re-preservation: the components of the elevator - up to one year, spare parts - up to 2.5 years. Re-preservation must be carried out by the owner of the lift.

The packing lists must indicate: the date and period of re-preservation, as well as the means of temporary corrosion protection.

4.4.2 Preservation and packing of wires and cables should be carried out taking into account the requirements of GOST 18690, electrical equipment (including harnesses) - in accordance with GOST 23216.

4.4.3 Packing of equipment and technical documentation of the elevator - in accordance with GOST 23170.

Ropes are packed in a polymer film in accordance with GOST 10354 or other NTD agreed with Gosgortekhnadzor, or in waterproof paper in accordance with GOST 8828 and GOST 515.

A rope wound into a coil must be tightly tied with soft wire (in accordance with GOST 3282 or other NTD) or a strand of the same rope, or with a tape in accordance with GOST 3560 (or other NTD) in at least four places evenly spaced around the circumference.

4.4.4 Packaging of lift equipment in a tropical climatic version must comply with the requirements of GOST 24634, while the timber for packaging must be impregnated with an antiseptic. Instead of antiseptic treatment, it is allowed to paint boxes in two layers with PF-115 gray paint in accordance with GOST 6465 or other similar paints.

4.4.5 Packing of elevator equipment sent to the Far North of the Russian Federation and hard-to-reach areas - in accordance with GOST 15846.

5 SAFETY REQUIREMENTS

The safety of elevators is ensured by meeting the set of requirements 4.1.1-4.1.22 (except for 4.1.15, 4.1.17-4.1.18, 4.1.21), sections 3, 5-7, 9 of this standard and PUBEL Gosgortechnadzor.

6 RULES OF ACCEPTANCE

6.1 Component parts (equipment) of the elevator (including spare parts and accessories) should be subjected to acceptance control by the manufacturer's technical control service in order to determine their suitability for shipment to the consumer.

6.2 Acceptance control of the components of the elevator must be statistical on an alternative basis in accordance with GOST 18242.

Parameters, dimensions, requirements to be controlled, sample size and types of defects must be indicated in the technical documentation for the elevator.

6.3 Acceptance inspection of the components of the elevator must have the following inspection plan and the acceptance level of defectiveness:

a) control plan:

Control level - II,

Control plan type - one-stage,

b) the acceptance level of defectiveness of the winch, gearbox (if it is produced as a spare part), lift door drive, speed limiter, safety devices, hydraulic buffer, car loading control device, shaft doors, car doors, critical springs (buffer springs, brakes, safety , cab hangers and counterweight, etc.), spare parts and accessories:

2.5% for significant defects;

6.5% for minor defects.

Acceptance level of defectiveness of other assembly units and equipment parts:

0% - for critical defects;

6.5% for significant defects.

The production cycle under continuous statistical control is one year.

6.4 Purchased products, materials and raw materials should be subject to incoming inspection in accordance with GOST 24297.

During the incoming inspection, the low-voltage complete device (ASSEMBLY) must be checked for functioning.

When the customer or the consumer of the elevators receives complaints or claims to the quality of the purchased product, the manufacturer of the elevator during the incoming inspection must use another more stringent type of control in accordance with GOST 18242.

6.5 Elevator components, parts and castings produced by other manufacturers Shall be visually inspected by the elevator manufacturer to detect possible damage to this equipment during transportation.

The manufacturer of equipment, parts and castings, upon receipt of claims from the manufacturer of the elevator, must inform him within 3 days of the decision taken to eliminate the defect.

6.6 Acceptance tests of the components (equipment) of the elevator

The components of the lift referred to in 6.3 must be subjected to acceptance tests by its manufacturer according to programs and procedures approved in the prescribed manner.

The sampling volume of samples of the elevator components is set by the elevator manufacturer and is indicated in the technical documentation.

6.7 Elevators of each model must be tested:

After making a prototype:

Preliminary;

Acceptance;

When mastering production - qualification;

For serial production:

Acceptance tests of the elevator components;

Periodic;

Typical.

6.8 The frequency of the elevator tests specified in 6.7, the number of elevators that should be subjected to these tests, and the number of elevators in the batch from which the elevator is selected for testing shall be in accordance with table 6.

6.9 Periodic testing

6.9.1 Periodic tests of the elevator are carried out in order to check the stability of the workmanship and the possibility of continuing its release.

Periodic tests should include verification of all mandatory requirements established by this standard and PUBEL Gosgortekhnadzor.

6.9.2 In case of unsatisfactory results of periodic tests at least one of the points of the program, repeated tests should be carried out on these points on a double number of the corresponding components of the lift, taken from the same batch. Retest results are final.

Table 6

Test type

Frequency of tests

Number of lifts

The number of lifts in the batch from which the lifts are selected for testing

Preliminary

One-time - after making prototypes

All prototypes of the elevator, the number of which is determined by the terms of reference for the development

Receiving

All pre-tested prototypes

Qualifying

When putting into production an elevator of this model

Not less than 3

Periodic

At least once every three years

Not less than 7 *

With every design change

Not less than 3

* When carrying out tests at the manufacturer, the elevators are selected from among those that have passed the acceptance control and are ready for shipment to the consumer. When carrying out tests at the operating facility, they are selected from the number of manufactured ones no more than 18 months before the start of the tests.

7 CONTROL METHODS

7.1 Requirements for measuring instruments

7.1.1 Measuring instruments shall be verified in accordance with the requirements of GOST 8.002 and GOST 8.513.

Test equipment must be certified in accordance with GOST 24555, non-standardized measuring instruments must pass metrological certification in accordance with GOST 8.326.

7.2 Test preparation

7.2.1 Prior to the acceptance and qualification tests of the elevator, tests for the reliability of the winch, drive of doors, car doors, shaft doors, speed limiters, safety devices, hydraulic buffers, and car loading control devices must be performed.

It is allowed not to carry out tests for the reliability of equipment borrowed from other elevators, provided that it has been tested earlier and the manufacturer has a justification for maintaining the reliability indicators under operating conditions.

A low-voltage complete device must have a document confirming its reliability.

7.2.2 Before carrying out periodic tests, the manufacturer must provide materials confirming the reliability indicators of the elevators.

Confirmation of reliability indicators is carried out on the basis of a test for the reliability of an elevator or its components (equipment) in the period between periodic tests or on the basis of the results of operational observations of the operation of similar elevators.

Methods and plans of tests for reliability and observations during operation - in accordance with GOST 27.410.

7.2.3 To conduct type tests of an elevator, in which equipment is used with changes that can affect the technical characteristics of the elevator and / or its operation, tests should be carried out for each changed equipment.

If the test results of the modified equipment are positive, it is allowed to carry out type tests of the elevator.

7.3 Carrying out elevator tests

7.3.1 Tests of elevators should be carried out in accordance with the Programs and test methods agreed in the prescribed manner.

7.3.1.1 Before the start of the lift tests, the manufacturer must have a "Certificate of technical readiness of the lift".

The tests must be carried out on the premises of the lift manufacturer. Carrying out tests of the elevator at the operation site must be agreed with the Gosgortekhnadzor.

It is not allowed to replace the tests of the elevator by testing its layout.

When testing group control of elevators with three or more elevators in a group, it is allowed to simulate this system.

When testing several elevators of the same type and type, it is allowed to determine the quantitative and qualitative characteristics of one elevator - a typical representative of the group (determined by the elevator developer). For the rest of the elevators in the group, characteristics that differ from the characteristics of the typical representative must be checked.

In case of unsatisfactory test results for one or several indicators, the resumption of repeated tests is allowed only after the causes of the deficiencies are established and their elimination.

8 TRANSPORTATION AND STORAGE

8.1 Transportation of elevator equipment is allowed to be carried out by any type of transport in accordance with the transportation rules applicable to them.

When transporting elevator equipment on ship decks, the elevator manufacturer must take into account the effect of a type III atmosphere in accordance with GOST 15150.

8.2 Conditions and terms of storage and transportation of elevator equipment, spare parts and accessories in the packaging and (or) preservation of the manufacturer must correspond to those indicated in Table 7.

Table 7

Climatic version of the elevator in accordance with GOST 15150

Elevator equipment

mechanical with installed electrical equipment

mechanical without electrical equipment

SPTA and ZIM

2 - group of conventional designation of the main parameters of the elevator (carrying capacity and rated speed), set in accordance with the methodology in force in the elevator industry of the CIS countries;

3 - an indication of the installation of an elevator - single (they do not indicate in the symbol), group (G) from group 2 - 4, 6 elevators (G2 - G4, G6);

4 - the number of elevator stops;

6 -

7 - indication of the presence of the elevator operating mode "transportation of fire departments" (P);

8 -

An example of a symbolic designation of a passenger elevator for residential buildings with the main dimensions and design according to GOST 5746, with a carrying capacity of 400 kg, with a nominal speed of 0.71 m / s, a single installation, with 10 stops, in the version for operation in a moderately cold climate zone , placement categories 4 and in an area with an intensity of seismic impact of 8 points, which does not have a mode of operation "transportation of fire brigades":

2 Scheme of the symbol of freight elevators

1 - type and type of elevator with parameters, basic dimensions and design in accordance with GOST 8823:

Regular freight elevator (LGO);

Freight release lift (LGV);

Freight elevator with monorail (LGOM);

2 - serial registration number of the elevator model;

3 - carrying capacity, kg;

4 - rated speed, m / s;

5 - lifting height, m;

6 - number of stops;

7 - an indication of the size of the cabin in terms of an elevator of a given carrying capacity - the first (the smaller one is not indicated in the symbol) or the second (larger) (B);

8 - cab type - checkpoint (Ex.), non-passable (Continuous);

10 - an indication of the execution of the elevator (execution without taking into account the seismic effect in the symbol is not indicated), taking into account the seismic effect (C) with an intensity of 7 - 9 points (C7 - C9);

11 - designation of this standard.

An example of a conventional designation of a conventional freight elevator with basic dimensions and design in accordance with GOST 8823, with serial registration number 922, carrying capacity 1000 kg, with a nominal speed of 0.4 m / s, lifting height 60 m, with 16 stops, with a walk-through cabin of the second dimensions, for operation in a moderately cold climate zone and placement category 4:

3 Scheme of symbolic designation of cargo small elevators

1 - type of elevator; LGM - small freight elevator with parameters, basic dimensions and design in accordance with GOST 8824;

2 - serial registration number of the elevator model;

3 - carrying capacity, kg;

4 - rated speed, m / s;

5 - lifting height, m;

6 - number of stops;

7 - view of the cabin - through (Well), blind (Nesqu.);

9 - designation of this standard.

An example of a symbolic designation of a small freight elevator with parameters, basic dimensions and design in accordance with GOST 8824, with registration number of model 958, carrying capacity 100 kg, with a nominal speed of 0.4 m / s, lifting height 45 m, with 14 stops, with blind cab, designed for operation in a moderately cold climate zone and with placement category 4:

APPENDIX B

(required)

LIST OF TECHNICAL DOCUMENTATION SET *

* Depending on the type and type of a particular elevator, the list of documents for its equipment is specified by the developer.

The set of technical documentation for the elevator includes the following documents:

Elevator passport according to PUBEL Gosgortekhnadzor with documents certifying the quality: winches, speed limiter, door drive, hydraulic buffer, cabin buffer springs and counterweight, brake springs, safety springs. NKU passport (stored together with the elevator passport);

Installation drawing (installation drawing, a sample of which has been approved by Gosgortekhnadzor) (2 copies);

Instructions for installation, start-up, regulation and running-in;

Technical description and operating instructions;

Basic electrical diagram with a list of elements (3 copies);

Description of the electric drive and automation (it is allowed to supply as part of the technical description and operating instructions);

Electrical wiring diagram of the LVL for elevator control (supplied with the LVCD);

Elevator wiring diagram;

Vedomosti SPTA and ZIM;

Replacement parts drawings (see Appendix B);

Assembly drawings (and specifications for them) of elevator equipment for: speed limiter, hydraulic buffer, winch, reducer, brake, clutch, branch block, cabin, safety devices, automatic door drive, shaft door, automatic and manual shaft door locks, wiring for machine room, mine and cabin, counterweight.

APPENDIX B

REPLACEMENT PARTS LIST *

* The parts indicated in the list are intended to replace those that have failed (wear, breakdown) during the operation of the elevator after the expiration of its warranty period

Traction pulley.

Brake shoe assembly.

Brake spring.

Cab slip shoe liner.

Cab shoe roller (s).

Sliding door insert for freight elevators.

Shoe for doors of passenger elevators.

Roller for the doors of freight elevators.

Roller for carriages of passenger elevator cabin doors.

Roller drove drive doors of passenger elevators.

Rubber stop for the drive of the cab doors.

Counterweight sliding shoe bushing.

Roller carriages of automatic sliding doors of the mine.

Roller rubberized for the lock of the doors of the mine.

Speed ​​limiter pulley.

Elevator traction rope outlet block.

V-belt drive pulleys of the cab door drive.

Rubber ring of the device for controlling the loading of the moving field of the cab.

Cab door drive belt.

Note - The list of details is specified for a specific elevator by its developer.

Key words: passenger elevators, freight and freight small elevators, technical requirements, safety requirements, acceptance rules, transportation and storage

1 area of ​​use. 1

3 Main parameters and dimensions .. 3

4 Technical requirements. 3

4.1 Characteristics. 3

4.2 Completeness. eight

4.3 Marking. nine

4.4 Packaging. nine

5 Safety requirements. nine

6 Acceptance rules. nine

6.6 Acceptance tests of the components (equipment) of the elevator. ten

6.9 Periodic testing. eleven

7 Control methods. eleven

7.1 Requirements for measuring instruments. eleven

7.2 Test preparation ... 11

7.3 Testing the elevator. 12

8 Transportation and storage. 12

9 Instructions for installation and operation. 13

10 Manufacturer's Warranties. 13